ABB ACS580 VFD
ABB ACS580 VFD code 5091: Safe torque off
The safe torque off function is active due to a broken safety circuit signal, stopping the drive.
- Code
- 5091
- Name
- Safe torque off
- Controller
- ABB ACS580 VFD
- Type
- Safety interlock
- What it does
- Fault: the equipment trips and stops
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- ACS580 Standard Control Program Firmware Manual, page 541
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Safe torque off function is active, that is, safety circuit signal(s) connected to connector STO is broken during start or run.
From ACS580 Standard Control Program Firmware Manual, page 541.
In plain words
The drive's safety circuit was tripped while the motor was running, causing it to stop.
What usually sets it off
- Safety circuit signal(s) connected to connector STO is broken during start or run
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does ABB ACS580 VFD code 5091 mean?
The safe torque off function is active due to a broken safety circuit signal, stopping the drive.
Is ABB ACS580 VFD code 5091 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents ABB ACS580 VFD code 5091?
ACS580 Standard Control Program Firmware Manual, page 541.
How do I fix ABB ACS580 VFD code 5091?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.