ABB ACS580 VFD
ABB ACS580 VFD code 7191: BC short circuit
A short circuit exists in the brake chopper IGBT, causing the drive to stop.
- Code
- 7191
- Name
- BC short circuit
- Controller
- ABB ACS580 VFD
- Type
- Overcurrent
- What it does
- Fault: the equipment trips and stops
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- ACS580 Standard Control Program Firmware Manual, page 545
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Short circuit in brake chopper IGBT.
From ACS580 Standard Control Program Firmware Manual, page 545.
In plain words
A short circuit has been detected in the drive's braking circuit.
What usually sets it off
- Short circuit in brake chopper IGBT
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does ABB ACS580 VFD code 7191 mean?
A short circuit exists in the brake chopper IGBT, causing the drive to stop.
Is ABB ACS580 VFD code 7191 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents ABB ACS580 VFD code 7191?
ACS580 Standard Control Program Firmware Manual, page 545.
How do I fix ABB ACS580 VFD code 7191?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.