Allen-Bradley PowerFlex 4M VFD
Allen-Bradley PowerFlex 4M VFD code F081: F081 Comm Loss
The drive stopped because the communication port lost its connection to the control network.
- Code
- F081
- Name
- F081 Comm Loss
- Controller
- Allen-Bradley PowerFlex 4M VFD
- Type
- Communication
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Comm Loss. RS-485 (DSI) port stopped communicating.
From the manufacturer's manual.
In plain words
The drive lost its data connection to whatever was controlling or monitoring it over the communication port. This is usually a loose or damaged communication cable rather than a problem with the motor.
What usually sets it off
- Loose or damaged RS-485 communication wiring
- Communication adapter unplugged or failed
- Controlling device (master) powered off or offline
- Electrical noise on the communication line
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Allen-Bradley PowerFlex 4M VFD is commonly fitted on booths from Global Finishing Solutions and Col-Met. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Allen-Bradley PowerFlex 4M VFD code F081 mean?
The drive stopped because the communication port lost its connection to the control network.
Is Allen-Bradley PowerFlex 4M VFD code F081 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Allen-Bradley PowerFlex 4M VFD code F081?
The manufacturer's manual.
How do I fix Allen-Bradley PowerFlex 4M VFD code F081?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Allen-Bradley PowerFlex 4M VFD codes
All 15 Allen-Bradley PowerFlex 4M VFD codes · Every fault code