Allen-Bradley PowerFlex 525 VFD
Allen-Bradley PowerFlex 525 VFD code F013: F013 Ground Fault
The drive stopped the motor because it detected a current path to earth ground at the output terminals.
- Code
- F013
- Name
- F013 Ground Fault
- Controller
- Allen-Bradley PowerFlex 525 VFD
- Type
- Ground fault
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
A current path to earth ground has been detected at one or more of the drive output terminals.
From the manufacturer's manual.
In plain words
The drive found electricity leaking to ground somewhere between it and the motor. Usually this means damaged motor wiring, moisture in a connection or motor, or a failing motor. This one needs the output wiring and motor checked before running again.
What usually sets it off
- Damaged or pinched motor cable shorting to ground
- Moisture or contamination in the motor or a junction box
- Motor winding insulation breakdown to the frame
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Allen-Bradley PowerFlex 525 VFD is commonly fitted on booths from Global Finishing Solutions, Col-Met and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Allen-Bradley PowerFlex 525 VFD code F013 mean?
The drive stopped the motor because it detected a current path to earth ground at the output terminals.
Is Allen-Bradley PowerFlex 525 VFD code F013 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Allen-Bradley PowerFlex 525 VFD code F013?
The manufacturer's manual.
How do I fix Allen-Bradley PowerFlex 525 VFD code F013?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Allen-Bradley PowerFlex 525 VFD codes
All 16 Allen-Bradley PowerFlex 525 VFD codes · Every fault code