Honeywell 7800 Series Burner Control (RM7800 / RM7840)

Honeywell 7800 Series Burner Control (RM7800 / RM7840) *Preignition ILK*: Preignition ILK

The burner locked out because a preignition safety interlock was not in its expected state before starting.

Safety first. This code involves a gas, flame or electrical hazard. Do not keep resetting it. Leave burner, gas train and high voltage work to a qualified technician. WERCS answers 24/7 at (877) 489-3727.
Code
*Preignition ILK*
Name
Preignition ILK
Controller
Honeywell 7800 Series Burner Control (RM7800 / RM7840)
Type
General fault
What it does
Lockout: the control shuts down and stays off until it is reset
Risk
RED Specialist territory
Reset
Needs a manual reset
Source
The manufacturer's manual

Updated July 22, 2026

How to fix it

Subscribers get:

  • What to do next, in plain words
  • Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)

What the manual says

Fault 10. Preignition Interlock fault during STANDBY. The preignition interlock (for example a valve proving or low fire proof) was not in its expected state before a start was allowed.

From the manufacturer's manual.

What usually sets it off

Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.

Where you find this controller

On paint and spray booths, the Honeywell 7800 Series Burner Control (RM7800 / RM7840) is commonly fitted on booths from Global Finishing Solutions, Garmat USA, Col-Met, Accudraft Paint Booths and Blowtherm USA. The same code means the same thing on any of them.

When to call a technician

This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.

Questions about this code

What does Honeywell 7800 Series Burner Control (RM7800 / RM7840) *Preignition ILK* mean?

The burner locked out because a preignition safety interlock was not in its expected state before starting.

Is Honeywell 7800 Series Burner Control (RM7800 / RM7840) *Preignition ILK* dangerous?

It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.

Which manual documents Honeywell 7800 Series Burner Control (RM7800 / RM7840) *Preignition ILK*?

The manufacturer's manual.

How do I fix Honeywell 7800 Series Burner Control (RM7800 / RM7840) *Preignition ILK*?

The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.

Other Honeywell 7800 Series Burner Control (RM7800 / RM7840) codes