Partlow MIC 2000 Temperature Controller
Partlow MIC 2000 Temperature Controller code Er 3: Er 3 (EPROM Checksum Failure)
A checksum test of the program memory has failed due to corrupted data, which stops the controller from operating.
- Code
- Er 3
- Name
- Er 3 (EPROM Checksum Failure)
- Controller
- Partlow MIC 2000 Temperature Controller
- Type
- General fault
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Clears on its own when the condition goes away
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Er 3 - EPROM Checksum Failure. the manual directs inspecting that the EPROM (U2) is properly seated on the Processor board.
From the manufacturer's manual.
In plain words
This is usually a hardware issue that needs the unit inspected or serviced.
What usually sets it off
- Corrupted program memory
- EPROM chip not seated properly in its socket
- Internal hardware fault
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Partlow MIC 2000 Temperature Controller is commonly fitted on booths from Col-Met, Accudraft Paint Booths and AFC. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Partlow MIC 2000 Temperature Controller code Er 3 mean?
A checksum test of the program memory has failed due to corrupted data, which stops the controller from operating.
Is Partlow MIC 2000 Temperature Controller code Er 3 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Partlow MIC 2000 Temperature Controller code Er 3?
The manufacturer's manual.
How do I fix Partlow MIC 2000 Temperature Controller code Er 3?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Partlow MIC 2000 Temperature Controller codes
All 6 Partlow MIC 2000 Temperature Controller codes · Every fault code