Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 86 / c: 87: c: 86 (fuel servomotor) / c: 87 (air servomotor)
The burner stops because a servomotor failed to reach its target position within tolerance or has an open circuit.
- Code
- c: 86 / c: 87
- Name
- c: 86 (fuel servomotor) / c: 87 (air servomotor)
- Controller
- Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
- Type
- Setup or parameter fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Servomotor error. Position target not reached within tolerance, circuit open, curve too steep in terms of train ratio, or section deviation versus last reference.
From the manufacturer's manual.
In plain words
A damper or valve motor could not reach its target position, or its wiring is open, or the commissioning curve is too steep between two points.
What usually sets it off
- Servomotor blocked or overloaded
- Open wiring to the servomotor
- Curve step greater than 31 degrees between two points
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 86 / c: 87 mean?
The burner stops because a servomotor failed to reach its target position within tolerance or has an open circuit.
Is Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 86 / c: 87 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 86 / c: 87?
The manufacturer's manual.
How do I fix Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 86 / c: 87?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes
All 24 Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes · Every fault code