RKI Eagle / Eagle 2 Multi-Gas Detector
RKI Eagle / Eagle 2 Multi-Gas Detector code STEL: STEL (appears next to the gas reading)
The short term exposure limit for gas has been reached, triggering flashing LEDs, a pulsing buzzer, and an activated backlight.
- Code
- STEL
- Name
- STEL (appears next to the gas reading)
- Controller
- RKI Eagle / Eagle 2 Multi-Gas Detector
- Type
- Gas alarm
- What it does
- Warning: the equipment keeps running and flags a problem
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
STEL Alarm. The short-term exposure limit for CO or H2S has been reached. STEL appears next to the gas reading, the alarm LED arrays flash once per second, the backlight turns on, and the buzzer pulses once per second.
From the manufacturer's manual.
In plain words
Your short-term exposure to a toxic gas, carbon monoxide or hydrogen sulfide, has reached the safety limit. Move to fresh air.
What usually sets it off
- A short spike or buildup of CO or H2S
- Toxic gas exposure over a roughly 15 minute window
- Inadequate ventilation during spraying or curing
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does RKI Eagle / Eagle 2 Multi-Gas Detector code STEL mean?
The short term exposure limit for gas has been reached, triggering flashing LEDs, a pulsing buzzer, and an activated backlight.
Is RKI Eagle / Eagle 2 Multi-Gas Detector code STEL dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents RKI Eagle / Eagle 2 Multi-Gas Detector code STEL?
The manufacturer's manual.
How do I fix RKI Eagle / Eagle 2 Multi-Gas Detector code STEL?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other RKI Eagle / Eagle 2 Multi-Gas Detector codes
All 9 RKI Eagle / Eagle 2 Multi-Gas Detector codes · Every fault code