Satronic / Honeywell TFI 812 Gas Burner Control Box
Satronic / Honeywell TFI 812 Gas Burner Control Box Reset button lamp lit (lockout): Illuminated reset button
The burner control enters a safety lockout due to a missing flame, weak flame signal, or low voltage, stopping the burner.
- Code
- Reset button lamp lit (lockout)
- Name
- Illuminated reset button
- Controller
- Satronic / Honeywell TFI 812 Gas Burner Control Box
- Type
- General fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Safety lockout. The TFI 812 locks out either after an attempted start with no flame (no ignition/no fuel, flame signal during pre-purge, or mains more than 15% low) or after the safety interval if the flame signal is absent, too weak, or the detector is dirty or defective.
From the manufacturer's manual.
In plain words
This control does not show numbered codes. The usual reasons are no flame at start-up or the flame detector not seeing a good flame.
What usually sets it off
- No ignition or no fuel at start-up
- Flame signal seen during pre-purge (stray light)
- No, or too weak, flame signal
- Dirty or defective flame detector
- Mains voltage more than 15% low
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Satronic / Honeywell TFI 812 Gas Burner Control Box Reset button lamp lit (lockout) mean?
The burner control enters a safety lockout due to a missing flame, weak flame signal, or low voltage, stopping the burner.
Is Satronic / Honeywell TFI 812 Gas Burner Control Box Reset button lamp lit (lockout) dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Satronic / Honeywell TFI 812 Gas Burner Control Box Reset button lamp lit (lockout)?
The manufacturer's manual.
How do I fix Satronic / Honeywell TFI 812 Gas Burner Control Box Reset button lamp lit (lockout)?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Satronic / Honeywell TFI 812 Gas Burner Control Box codes
All 1 Satronic / Honeywell TFI 812 Gas Burner Control Box codes · Every fault code