Siemens LME7 Series Burner Control
Siemens LME7 Series Burner Control Loc 2: No establishment of flame at the end of safety time
The Siemens flame safeguard locks out the burner because a flame was not established at the end of the safety time.
- Code
- Loc 2
- Name
- No establishment of flame at the end of safety time
- Controller
- Siemens LME7 Series Burner Control
- Type
- Flame failure
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Siemens LME7 flame safeguard lockout, meaning: No establishment of flame at the end of safety time.
From the manufacturer's manual.
In plain words
The burner did not prove a flame within the safety time and locked out.
What usually sets it off
- Gas input too high or too low for a direct spark oven
- Weak or non-existent spark
- Dirty igniter
- No power to the ignition transformer
- Open circuit between the ignition transformer and igniter
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Siemens LME7 Series Burner Control Loc 2 mean?
The Siemens flame safeguard locks out the burner because a flame was not established at the end of the safety time.
Is Siemens LME7 Series Burner Control Loc 2 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Siemens LME7 Series Burner Control Loc 2?
The manufacturer's manual.
How do I fix Siemens LME7 Series Burner Control Loc 2?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Siemens LME7 Series Burner Control codes
All 11 Siemens LME7 Series Burner Control codes · Every fault code