Siemens SINAMICS V20 VFD
Siemens SINAMICS V20 VFD code F350: Configuration vector for the converter failed
The hardware does not match the programmed configuration vector, which causes the drive to trip and stop the booth.
- Code
- F350
- Name
- Configuration vector for the converter failed
- Controller
- Siemens SINAMICS V20 VFD
- Type
- Internal fault
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- SINAMICS V20 Operating Instructions (03/2021), page 351
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
During startup the converter checks if the configuration vector (SZL vector) has been programmed correctly and if hardware matches the programmed vector. If not the converter will trip.
From SINAMICS V20 Operating Instructions (03/2021), page 351.
In plain words
The drive's internal hardware or software configuration is mismatched or failed.
What usually sets it off
- Internal failure - no hardware configuration vector available
- Internal failure - no software configuration vector available
- Internal failure - converter code not supported
- Internal failure - software vector not possible
- Wrong power module fitted
- Internal failure - wrong I/O board fitted
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Siemens SINAMICS V20 VFD code F350 mean?
The hardware does not match the programmed configuration vector, which causes the drive to trip and stop the booth.
Is Siemens SINAMICS V20 VFD code F350 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.