WERCSWERCSDiagnose

Weishaupt W-FM 200 Combustion Manager

Weishaupt W-FM 200 Combustion Manager code 31: Loc.c 31 / Err.c 31

The burner locks out because the valve proving test detected a leaking first valve or an unopened second valve.

Safety first. This code involves a gas, flame or electrical hazard. Do not keep resetting it. Leave burner, gas train and high voltage work to a qualified technician. WERCS answers 24/7 at (877) 489-3727.
Code
31
Name
Loc.c 31 / Err.c 31
Controller
Weishaupt W-FM 200 Combustion Manager
Type
Gas valve proving
What it does
Lockout: the control shuts down and stays off until it is reset
Risk
RED Specialist territory
Reset
Needs a manual reset
Source
The manufacturer's manual

Updated July 23, 2026

How to fix it

Subscribers get:

  • What to do next, in plain words
  • The step by step check for this problem, one check at a time
  • Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)

What usually sets it off

Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.

When to call a technician

This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.

Questions about this code

What does Weishaupt W-FM 200 Combustion Manager code 31 mean?

The burner locks out because the valve proving test detected a leaking first valve or an unopened second valve.

Is Weishaupt W-FM 200 Combustion Manager code 31 dangerous?

It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.

Which manual documents Weishaupt W-FM 200 Combustion Manager code 31?

The manufacturer's manual.

How do I fix Weishaupt W-FM 200 Combustion Manager code 31?

The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.

Other Weishaupt W-FM 200 Combustion Manager codes

All 16 Weishaupt W-FM 200 Combustion Manager codes · Every fault code