Yaskawa GA500 AC Drive
Yaskawa GA500 AC Drive code bUS: Option Communication Error
The drive lost its signal from the controller due to wiring or interference, causing the motor to stop.
- Code
- bUS
- Name
- Option Communication Error
- Controller
- Yaskawa GA500 AC Drive
- Type
- Communication
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- GA500 Installation & Primary Operation (TOEPC7106170Y), page 117
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
The drive did not receive a signal from the controller, or there is a wiring/interference issue.
From GA500 Installation & Primary Operation (TOEPC7106170Y), page 117.
In plain words
The drive lost communication with an optional add-on card.
What usually sets it off
- The drive did not receive a signal from the controller
- The communications cable wiring is incorrect
- There is a short-circuit in the communications cable or it is not connected
- Electrical interference caused a communication data error
- The option is incorrectly installed or damaged
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa GA500 AC Drive code bUS mean?
The drive lost its signal from the controller due to wiring or interference, causing the motor to stop.
Is Yaskawa GA500 AC Drive code bUS dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa GA500 AC Drive code bUS?
GA500 Installation & Primary Operation (TOEPC7106170Y), page 117.
How do I fix Yaskawa GA500 AC Drive code bUS?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.