Yaskawa GA500 AC Drive
Yaskawa GA500 AC Drive code LF2: Output Current Imbalance
An imbalance in the output current to the motor has caused the drive to stop operating.
- Code
- LF2
- Name
- Output Current Imbalance
- Controller
- Yaskawa GA500 AC Drive
- Type
- General fault
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- GA500 Installation & Primary Operation (TOEPC7106170Y), page 124
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
There is an imbalance in the output current to the motor.
From GA500 Installation & Primary Operation (TOEPC7106170Y), page 124.
In plain words
The electrical current going to the motor is unbalanced.
What usually sets it off
- Phase loss occurred in the wiring on the output side of the drive
- The output terminal screws of the drive are loose
- There is not balance between the three phases of the PM motor impedance
- The drive output circuit is broken
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa GA500 AC Drive code LF2 mean?
An imbalance in the output current to the motor has caused the drive to stop operating.
Is Yaskawa GA500 AC Drive code LF2 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa GA500 AC Drive code LF2?
GA500 Installation & Primary Operation (TOEPC7106170Y), page 124.
How do I fix Yaskawa GA500 AC Drive code LF2?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.