Yaskawa GA500 AC Drive
Yaskawa GA500 AC Drive code oPE05: Run Cmd/Freq Ref Source Sel Err
The run command or frequency reference assignment is incorrect, which prevents the drive from operating the booth.
- Code
- oPE05
- Name
- Run Cmd/Freq Ref Source Sel Err
- Controller
- Yaskawa GA500 AC Drive
- Type
- Setup or parameter fault
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- GA500 Installation & Primary Operation (TOEPC7106170Y), page 158
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
The setting to assign the Run command or frequency reference to an option card or pulse train is incorrect.
From GA500 Installation & Primary Operation (TOEPC7106170Y), page 158.
In plain words
The drive is programmed to look for a command from a card that isn't installed.
What usually sets it off
- The setting to assign the Run command or frequency reference to an option card or the pulse train input is incorrect
- B1-01 = 3 is set, but there is no option card connected
- B1-02 = 3 is set, but there is no option card connected
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa GA500 AC Drive code oPE05 mean?
The run command or frequency reference assignment is incorrect, which prevents the drive from operating the booth.
Is Yaskawa GA500 AC Drive code oPE05 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa GA500 AC Drive code oPE05?
GA500 Installation & Primary Operation (TOEPC7106170Y), page 158.
How do I fix Yaskawa GA500 AC Drive code oPE05?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.