WERCSWERCSDiagnose

Fireye MicroM Burner Control

Fireye MicroM Burner Control Lockout Check BLOWN FUSE

No power was detected on terminal three due to a blown chassis fuse, causing the control to lock out.

Safety first. This code involves a gas, flame or electrical hazard. Do not keep resetting it. Leave burner, gas train and high voltage work to a qualified technician. WERCS answers 24/7 at (877) 489-3727.
Code
Lockout Check BLOWN FUSE
Name
Lockout Check BLOWN FUSE
Controller
Fireye MicroM Burner Control
Type
General fault
What it does
Lockout: the control shuts down and stays off until it is reset
Risk
RED Specialist territory
Reset
Needs a manual reset
Source
The manufacturer's manual

Updated July 22, 2026

How to fix it

Subscribers get:

  • What to do next, in plain words
  • Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)

What the manual says

MicroM lockout message 59 (hex 3B). No power was detected on terminal 3, indicating the field-replaceable chassis fuse is open (blown), typically from an overload on terminals 3, 4, or 5. The control locks out.

From the manufacturer's manual.

In plain words

The control lost power to its output because the fuse blew, usually from a short or overload in the pilot valve or igniter circuit.

What usually sets it off

Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.

Where you find this controller

On paint and spray booths, the Fireye MicroM Burner Control is commonly fitted on booths from SprayBake and AFC. The same code means the same thing on any of them.

When to call a technician

This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.

Questions about this code

What does Fireye MicroM Burner Control Lockout Check BLOWN FUSE mean?

No power was detected on terminal three due to a blown chassis fuse, causing the control to lock out.

Is Fireye MicroM Burner Control Lockout Check BLOWN FUSE dangerous?

It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.

Which manual documents Fireye MicroM Burner Control Lockout Check BLOWN FUSE?

The manufacturer's manual.

How do I fix Fireye MicroM Burner Control Lockout Check BLOWN FUSE?

The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.

Other Fireye MicroM Burner Control codes

All 7 Fireye MicroM Burner Control codes · Every fault code