Fireye MicroM Burner Control
Fireye MicroM Burner Control Lockout Check BLOWN FUSE
No power was detected on terminal three due to a blown chassis fuse, causing the control to lock out.
- Code
- Lockout Check BLOWN FUSE
- Name
- Lockout Check BLOWN FUSE
- Controller
- Fireye MicroM Burner Control
- Type
- General fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
MicroM lockout message 59 (hex 3B). No power was detected on terminal 3, indicating the field-replaceable chassis fuse is open (blown), typically from an overload on terminals 3, 4, or 5. The control locks out.
From the manufacturer's manual.
In plain words
The control lost power to its output because the fuse blew, usually from a short or overload in the pilot valve or igniter circuit.
What usually sets it off
- Shorted pilot valve or igniter wiring
- Overload on the pilot, ignition, or main valve outputs
- Defective fuse
- Miswired output terminals
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Fireye MicroM Burner Control is commonly fitted on booths from SprayBake and AFC. The same code means the same thing on any of them.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Fireye MicroM Burner Control Lockout Check BLOWN FUSE mean?
No power was detected on terminal three due to a blown chassis fuse, causing the control to lock out.
Is Fireye MicroM Burner Control Lockout Check BLOWN FUSE dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Fireye MicroM Burner Control Lockout Check BLOWN FUSE?
The manufacturer's manual.
How do I fix Fireye MicroM Burner Control Lockout Check BLOWN FUSE?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.