Fireye MicroM Burner Control
Fireye MicroM Burner Control Lockout Flame Fail - PTFI
The burner locked out and triggered an alarm because the pilot flame was not detected during the ignition trial.
- Code
- Lockout Flame Fail - PTFI
- Name
- Lockout Flame Fail - PTFI
- Controller
- Fireye MicroM Burner Control
- Type
- Flame failure
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
MicroM lockout message 7 (hex 07). Pilot flame was not detected at the end of the Pilot Trial For Ignition period, so the pilot valve and spark are de-energized, the alarm is energized, and the control locks out.
From the manufacturer's manual.
What usually sets it off
- No gas or closed manual gas valve
- Dirty or mispositioned flame scanner or flame rod
- Weak or misaligned pilot
- Failed pilot valve or ignition transformer
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Fireye MicroM Burner Control is commonly fitted on booths from SprayBake and AFC. The same code means the same thing on any of them.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Fireye MicroM Burner Control Lockout Flame Fail - PTFI mean?
The burner locked out and triggered an alarm because the pilot flame was not detected during the ignition trial.
Is Fireye MicroM Burner Control Lockout Flame Fail - PTFI dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Fireye MicroM Burner Control Lockout Flame Fail - PTFI?
The manufacturer's manual.
How do I fix Fireye MicroM Burner Control Lockout Flame Fail - PTFI?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.