Riello RDB 2.2 Burner Control (MO 535 - MPF)
Riello RDB 2.2 Burner Control (MO 535 - MPF) Green + red blinking (0.5s/0.5s): Reset button: green and red blinking
The burner control locks out because it detects extraneous light or a false flame signal.
- Code
- Green + red blinking (0.5s/0.5s)
- Name
- Reset button: green and red blinking
- Controller
- Riello RDB 2.2 Burner Control (MO 535 - MPF)
- Type
- Flame failure
- What it does
- Warning: the equipment keeps running and flags a problem
- Risk
- RED Specialist territory
- Reset
- Clears on its own when the condition goes away
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Extraneous light / false flame signal detected.
From the manufacturer's manual.
In plain words
Often stray light or a sensor that thinks it still sees a flame.
What usually sets it off
- Stray daylight or another light source reaching the photocell
- Photocell dirty or faulty
- Residual flame or hot refractory glowing
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Riello RDB 2.2 Burner Control (MO 535 - MPF) Green + red blinking (0.5s/0.5s) mean?
The burner control locks out because it detects extraneous light or a false flame signal.
Is Riello RDB 2.2 Burner Control (MO 535 - MPF) Green + red blinking (0.5s/0.5s) dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Riello RDB 2.2 Burner Control (MO 535 - MPF) Green + red blinking (0.5s/0.5s)?
The manufacturer's manual.
How do I fix Riello RDB 2.2 Burner Control (MO 535 - MPF) Green + red blinking (0.5s/0.5s)?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Riello RDB 2.2 Burner Control (MO 535 - MPF) codes
All 9 Riello RDB 2.2 Burner Control (MO 535 - MPF) codes · Every fault code