Riello RDB 2.2 Burner Control (MO 535 - MPF)
Riello RDB 2.2 Burner Control (MO 535 - MPF) Red + orange inverted flashing (2.5s/0.5s): Reset button: red and orange inverted flashing
The burner control locks out due to a fan motor error, stopping the combustion process.
- Code
- Red + orange inverted flashing (2.5s/0.5s)
- Name
- Reset button: red and orange inverted flashing
- Controller
- Riello RDB 2.2 Burner Control (MO 535 - MPF)
- Type
- General fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Lockout due to fan motor error.
From the manufacturer's manual.
In plain words
The control box detected a problem with the fan motor and locked out.
What usually sets it off
- Fan motor not running or wrong speed
- Motor capacitor or winding fault
- Wiring fault to the motor
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Riello RDB 2.2 Burner Control (MO 535 - MPF) Red + orange inverted flashing (2.5s/0.5s) mean?
The burner control locks out due to a fan motor error, stopping the combustion process.
Is Riello RDB 2.2 Burner Control (MO 535 - MPF) Red + orange inverted flashing (2.5s/0.5s) dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Riello RDB 2.2 Burner Control (MO 535 - MPF) Red + orange inverted flashing (2.5s/0.5s)?
The manufacturer's manual.
How do I fix Riello RDB 2.2 Burner Control (MO 535 - MPF) Red + orange inverted flashing (2.5s/0.5s)?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Riello RDB 2.2 Burner Control (MO 535 - MPF) codes
All 9 Riello RDB 2.2 Burner Control (MO 535 - MPF) codes · Every fault code