Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 2: c: 2 (alternating with d: 1 / d: 2 / d: 4)
The burner control box locks out because no flame was detected at the end of the ignition safety time.
- Code
- c: 2
- Name
- c: 2 (alternating with d: 1 / d: 2 / d: 4)
- Controller
- Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
- Type
- Ignition lockout
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
No flame at the end of the ignition safety time. Diagnostics: d1 = no flame at end of TSA1; d2 = no flame at end of TSA2; d4 = no flame at end of TSA1 (software V02.00).
From the manufacturer's manual.
What usually sets it off
- No or insufficient fuel at ignition
- Ignition electrode or transformer fault
- Flame detector not seeing the flame
- Gas valve not opening
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 2 mean?
The burner control box locks out because no flame was detected at the end of the ignition safety time.
Is Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 2 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 2?
The manufacturer's manual.
How do I fix Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 2?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes
All 24 Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes · Every fault code