Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 20: c: 20 (alternating with d: 0/1)
The system detected a lack of minimum gas or oil pressure, which locks out the burner at startup.
- Code
- c: 20
- Name
- c: 20 (alternating with d: 0/1)
- Controller
- Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
- Type
- General fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Pmin. d0 = minimum gas/oil pressure absent; d1 = scarcity of gas, lockout at start.
From the manufacturer's manual.
In plain words
The fuel supply pressure is too low or missing, so the burner cannot run safely.
What usually sets it off
- Gas or oil supply pressure below minimum
- Supply valve closed or line interruption
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 20 mean?
The system detected a lack of minimum gas or oil pressure, which locks out the burner at startup.
Is Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 20 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 20?
The manufacturer's manual.
How do I fix Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 20?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes
All 24 Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes · Every fault code