Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 70: c: 70 (with d: 23 / d: 26)
A fuel and air checking error occurred during modulation position calculation, which locks out the burner.
- Code
- c: 70
- Name
- c: 70 (with d: 23 / d: 26)
- Controller
- Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
- Type
- Setup or parameter fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Fuel/air checking error: calculation of position in modulation. d23 = invalid load; d26 = curve points not defined.
From the manufacturer's manual.
In plain words
The control box could not work out a valid fuel-to-air position on its modulation curve, usually because the commissioning curve is not set up.
What usually sets it off
- Air/fuel curve not commissioned
- Missing curve points
- Invalid load setting
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 70 mean?
A fuel and air checking error occurred during modulation position calculation, which locks out the burner.
Is Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 70 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 70?
The manufacturer's manual.
How do I fix Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 70?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes
All 24 Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes · Every fault code