Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 93: c: 93 (with d: 3)
The burner locks out because there is a flame signal acquisition error caused by a short circuit in the sensor.
- Code
- c: 93
- Name
- c: 93 (with d: 3)
- Controller
- Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display)
- Type
- Sensor fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Flame signal acquisition error. d3 = short circuit of the sensor (QRB).
From the manufacturer's manual.
In plain words
The flame sensor circuit looks shorted to the control box, so it cannot trust the flame signal.
What usually sets it off
- Short circuit in the QRB flame sensor wiring
- Faulty flame detector
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 93 mean?
The burner locks out because there is a flame signal acquisition error caused by a short circuit in the sensor.
Is Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 93 dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 93?
The manufacturer's manual.
How do I fix Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) code c: 93?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes
All 24 Riello RS/E BLU Burner Control (REC 27.100A2 with RDI21 display) codes · Every fault code