Satronic / Honeywell DKG 972 Gas Burner Control
Satronic / Honeywell DKG 972 Gas Burner Control 1 short + 2 long flashes: Flash-Code: 1 short then 2 long pulses (low mains voltage)
The mains voltage dropped too low, causing the burner control box to lock out until voltage recovers.
- Code
- 1 short + 2 long flashes
- Name
- Flash-Code: 1 short then 2 long pulses (low mains voltage)
- Controller
- Satronic / Honeywell DKG 972 Gas Burner Control
- Type
- General fault
- What it does
- Warning: the equipment keeps running and flags a problem
- Risk
- GREEN In your wheelhouse
- Reset
- Clears on its own when the condition goes away
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Low mains voltage. Below 160 V the box locks out; it restarts automatically once voltage rises above 187 V.
From the manufacturer's manual.
In plain words
The supply voltage dropped too low for safe operation. The control pauses and starts the burner again on its own once the voltage recovers. If it stays low it will lock out.
What usually sets it off
- Brown-out or sagging mains supply
- Undersized or shared circuit
- Loose supply connection
- Generator or inverter voltage instability
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This one is usually within reach of in-house maintenance. Call a booth technician if it keeps returning or shows up together with a burner, gas or airflow fault. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Satronic / Honeywell DKG 972 Gas Burner Control 1 short + 2 long flashes mean?
The mains voltage dropped too low, causing the burner control box to lock out until voltage recovers.
Is Satronic / Honeywell DKG 972 Gas Burner Control 1 short + 2 long flashes dangerous?
It is graded green: in a working tech's wheelhouse with standard tools and low risk.
Which manual documents Satronic / Honeywell DKG 972 Gas Burner Control 1 short + 2 long flashes?
The manufacturer's manual.
How do I fix Satronic / Honeywell DKG 972 Gas Burner Control 1 short + 2 long flashes?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Satronic / Honeywell DKG 972 Gas Burner Control codes