Satronic / Honeywell DKG 972 Gas Burner Control
Satronic / Honeywell DKG 972 Gas Burner Control 2 short + 8 long flashes: Flash-Code: 2 short then 8 long pulses (manual/external lockout)
The burner control is in a manual or external lockout state, stopping the heating system.
- Code
- 2 short + 8 long flashes
- Name
- Flash-Code: 2 short then 8 long pulses (manual/external lockout)
- Controller
- Satronic / Honeywell DKG 972 Gas Burner Control
- Type
- General fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Manual or external lockout: the unit was deliberately placed into lockout via the internal button or an external button on terminal 9/A.
From the manufacturer's manual.
In plain words
Someone forced the control into lockout, either with the button on the unit or a remote lockout button.
What usually sets it off
- External remote lockout button activated
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Satronic / Honeywell DKG 972 Gas Burner Control 2 short + 8 long flashes mean?
The burner control is in a manual or external lockout state, stopping the heating system.
Is Satronic / Honeywell DKG 972 Gas Burner Control 2 short + 8 long flashes dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Satronic / Honeywell DKG 972 Gas Burner Control 2 short + 8 long flashes?
The manufacturer's manual.
How do I fix Satronic / Honeywell DKG 972 Gas Burner Control 2 short + 8 long flashes?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Satronic / Honeywell DKG 972 Gas Burner Control codes
All 5 Satronic / Honeywell DKG 972 Gas Burner Control codes · Every fault code