Satronic / Honeywell DKO 970/972 Oil Burner Control
Satronic / Honeywell DKO 970/972 Oil Burner Control 1 short + 4 long flashes: Flash-Code: 1 short then 4 long pulses
The oil burner control locks out because a flame was not established within the safety time.
- Code
- 1 short + 4 long flashes
- Name
- Flash-Code: 1 short then 4 long pulses
- Controller
- Satronic / Honeywell DKO 970/972 Oil Burner Control
- Type
- Flame failure
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Lockout within the lockout safety time: no flame establishment.
From the manufacturer's manual.
In plain words
The oil burner tried to light but no flame was proven within the safety time, so the control locked out and cut fuel.
What usually sets it off
- No ignition
- No oil or oil not reaching the burner
- Fouled or misadjusted electrodes
- Flame detector not sensing the flame
- Poor burner earth
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Satronic / Honeywell DKO 970/972 Oil Burner Control 1 short + 4 long flashes mean?
The oil burner control locks out because a flame was not established within the safety time.
Is Satronic / Honeywell DKO 970/972 Oil Burner Control 1 short + 4 long flashes dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Satronic / Honeywell DKO 970/972 Oil Burner Control 1 short + 4 long flashes?
The manufacturer's manual.
How do I fix Satronic / Honeywell DKO 970/972 Oil Burner Control 1 short + 4 long flashes?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Satronic / Honeywell DKO 970/972 Oil Burner Control codes
All 5 Satronic / Honeywell DKO 970/972 Oil Burner Control codes · Every fault code