Satronic / Honeywell DKO 970/972 Oil Burner Control
Satronic / Honeywell DKO 970/972 Oil Burner Control 2 short + 8 long flashes: Flash-Code: 2 short then 8 long pulses (manual/external lockout)
The oil burner control is deliberately placed into a manual or external lockout state, stopping operation.
- Code
- 2 short + 8 long flashes
- Name
- Flash-Code: 2 short then 8 long pulses (manual/external lockout)
- Controller
- Satronic / Honeywell DKO 970/972 Oil Burner Control
- Type
- General fault
- What it does
- Lockout: the control shuts down and stays off until it is reset
- Risk
- RED Specialist territory
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 23, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Manual or external lockout: the unit was deliberately placed into lockout via the internal button or an external button on terminal 9/A.
From the manufacturer's manual.
In plain words
The control was manually forced into lockout, on the unit or via a remote button.
What usually sets it off
- Internal button held more than 3 seconds
- External remote lockout button
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Satronic / Honeywell DKO 970/972 Oil Burner Control 2 short + 8 long flashes mean?
The oil burner control is deliberately placed into a manual or external lockout state, stopping operation.
Is Satronic / Honeywell DKO 970/972 Oil Burner Control 2 short + 8 long flashes dangerous?
It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.
Which manual documents Satronic / Honeywell DKO 970/972 Oil Burner Control 2 short + 8 long flashes?
The manufacturer's manual.
How do I fix Satronic / Honeywell DKO 970/972 Oil Burner Control 2 short + 8 long flashes?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.
Other Satronic / Honeywell DKO 970/972 Oil Burner Control codes
All 5 Satronic / Honeywell DKO 970/972 Oil Burner Control codes · Every fault code