Siemens SINAMICS V20 VFD

Siemens SINAMICS V20 VFD code A523: Output current ripple too high

The calculated output ripple level has exceeded the safe threshold, which triggers a warning without stopping the booth equipment.

Safety first. This code involves a gas, flame or electrical hazard. Do not keep resetting it. Leave burner, gas train and high voltage work to a qualified technician. WERCS answers 24/7 at (877) 489-3727.
Code
A523
Name
Output current ripple too high
Controller
Siemens SINAMICS V20 VFD
Type
Power supply
What it does
Warning: the equipment keeps running and flags a problem
Risk
RED Specialist territory
Reset
Clears on its own when the condition goes away
Source
SINAMICS V20 Operating Instructions (03/2021), page 354

Updated November 4, 2026

How to fix it

Subscribers get:

  • What to do next, in plain words
  • What the manual says to do, and the page it is on
  • Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)

What the manual says

The calculated output ripple level has exceeded the safe threshold.

From SINAMICS V20 Operating Instructions (03/2021), page 354.

In plain words

The power going to the motor is unstable, possibly due to a loose wire or severe motor vibration.

What usually sets it off

Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.

When to call a technician

This is specialist territory. It involves a burner, gas, flame or a safety lockout. Do not keep resetting it and do not bypass an interlock to get the booth running. Call a qualified booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.

Questions about this code

What does Siemens SINAMICS V20 VFD code A523 mean?

The calculated output ripple level has exceeded the safe threshold, which triggers a warning without stopping the booth equipment.

Is Siemens SINAMICS V20 VFD code A523 dangerous?

It is graded red, specialist territory: it involves a burner, gas, flame or safety lockout, so leave the repair to a qualified technician.

Which manual documents Siemens SINAMICS V20 VFD code A523?

SINAMICS V20 Operating Instructions (03/2021), page 354.

How do I fix Siemens SINAMICS V20 VFD code A523?

The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.

Other Siemens SINAMICS V20 VFD codes