Siemens SINAMICS V20 VFD
Siemens SINAMICS V20 VFD code A910: Vdc_max controller deactivated
The maximum voltage controller has deactivated due to high supply voltage, which triggers a warning without stopping the booth.
- Code
- A910
- Name
- Vdc_max controller deactivated
- Controller
- Siemens SINAMICS V20 VFD
- Type
- High voltage
- What it does
- Warning: the equipment keeps running and flags a problem
- Risk
- GREEN In your wheelhouse
- Reset
- Clears on its own when the condition goes away
- Source
- SINAMICS V20 Operating Instructions (03/2021), page 354
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Occurs if main supply voltage is permanently too high, if motor is driven by an active load, or at very high load inertias when ramping down.
From SINAMICS V20 Operating Instructions (03/2021), page 354.
In plain words
The drive has disabled its overvoltage controller because the incoming power is too high or the motor is generating too much power.
What usually sets it off
- Main supply voltage (P0210) is permanently too high
- Motor is driven by an active load, causing motor to go into regenerative mode
- At very high load inertias, when ramping down
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
This one is usually within reach of in-house maintenance. Call a booth technician if it keeps returning or shows up together with a burner, gas or airflow fault. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Siemens SINAMICS V20 VFD code A910 mean?
The maximum voltage controller has deactivated due to high supply voltage, which triggers a warning without stopping the booth.
Is Siemens SINAMICS V20 VFD code A910 dangerous?
It is graded green: in a working tech's wheelhouse with standard tools and low risk.
Which manual documents Siemens SINAMICS V20 VFD code A910?
SINAMICS V20 Operating Instructions (03/2021), page 354.
How do I fix Siemens SINAMICS V20 VFD code A910?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.