Yaskawa GA500 AC Drive
Yaskawa GA500 AC Drive code rH: Braking Resistor Overheat
The braking resistor is overheating from excessive energy, which causes the drive to stop the motor.
- Code
- rH
- Name
- Braking Resistor Overheat
- Controller
- Yaskawa GA500 AC Drive
- Type
- Over temperature
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- GA500 Installation & Primary Operation (TOEPC7106170Y), page 138
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
The braking resistor is overheating due to excessive regenerative energy.
From GA500 Installation & Primary Operation (TOEPC7106170Y), page 138.
In plain words
The braking resistor is getting too hot from stopping the motor too often or too fast. Let it cool down and consider slowing the stop time.
What usually sets it off
- The deceleration time is too short and there is too much regenerative energy flowing back into the drive
- The braking load is too heavy
- The braking resistor is not sufficient
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa GA500 AC Drive code rH mean?
The braking resistor is overheating from excessive energy, which causes the drive to stop the motor.
Is Yaskawa GA500 AC Drive code rH dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa GA500 AC Drive code rH?
GA500 Installation & Primary Operation (TOEPC7106170Y), page 138.
How do I fix Yaskawa GA500 AC Drive code rH?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.