Yaskawa GA500 AC Drive
Yaskawa GA500 AC Drive code ov: Overvoltage
The internal bus voltage exceeded the safe detection level, causing the drive to stop the motor.
- Code
- ov
- Name
- Overvoltage
- Controller
- Yaskawa GA500 AC Drive
- Type
- High voltage
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- GA500 Installation & Primary Operation (TOEPC7106170Y), page 135
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
The DC bus voltage exceeded the overvoltage detection level.
From GA500 Installation & Primary Operation (TOEPC7106170Y), page 135.
In plain words
The drive received too much voltage, often caused by stopping a heavy load too quickly.
What usually sets it off
- The deceleration time is too short and too much regenerative energy is flowing back into the drive
- The acceleration time is too short
- The braking load is too large
- There are surge voltages in the input power supply
- The drive output cable or motor is shorted to ground
- The power supply voltage is too high
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa GA500 AC Drive code ov mean?
The internal bus voltage exceeded the safe detection level, causing the drive to stop the motor.
Is Yaskawa GA500 AC Drive code ov dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa GA500 AC Drive code ov?
GA500 Installation & Primary Operation (TOEPC7106170Y), page 135.
How do I fix Yaskawa GA500 AC Drive code ov?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.