Yaskawa GA500 AC Drive
Yaskawa GA500 AC Drive code oC: Overcurrent
The drive output current exceeded the safe detection level, causing the drive to stop the motor.
- Code
- oC
- Name
- Overcurrent
- Controller
- Yaskawa GA500 AC Drive
- Type
- Overcurrent
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- GA500 Installation & Primary Operation (TOEPC7106170Y), page 126
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
The drive output current exceeded the overcurrent detection level.
From GA500 Installation & Primary Operation (TOEPC7106170Y), page 126.
In plain words
The motor drew too much electrical current.
What usually sets it off
- The load is too heavy
- Overheating caused damage to the motor or the motor insulation is not satisfactory
- The motor main circuit cable is contacting ground to make a short circuit
- A short circuit or ground fault on the drive output side caused damage to the output transistor
- The acceleration time is too short
- The drive is trying to operate a specialized motor or a motor that is larger than the maximum applicable motor output
- A magnetic contactor was switched at the output
- The V/f pattern settings are incorrect
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa GA500 AC Drive code oC mean?
The drive output current exceeded the safe detection level, causing the drive to stop the motor.
Is Yaskawa GA500 AC Drive code oC dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa GA500 AC Drive code oC?
GA500 Installation & Primary Operation (TOEPC7106170Y), page 126.
How do I fix Yaskawa GA500 AC Drive code oC?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.