Yaskawa GA500 AC Drive
Yaskawa GA500 AC Drive code Uv1: DC Bus Undervoltage
The DC bus voltage dropped below the detection level, causing the drive to shut down the equipment.
- Code
- Uv1
- Name
- DC Bus Undervoltage
- Controller
- Yaskawa GA500 AC Drive
- Type
- Low voltage
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- GA500 Installation & Primary Operation (TOEPC7106170Y), page 140
Updated November 4, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- What the manual says to do, and the page it is on
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
The DC bus voltage dropped below the undervoltage detection level.
From GA500 Installation & Primary Operation (TOEPC7106170Y), page 140.
In plain words
The drive is not getting enough power.
What usually sets it off
- There is a phase loss in the drive input power
- There is loose wiring in the drive input power terminals
- The drive input power voltage is changing too much
- There was a loss of power
- The main circuit capacitors have become unserviceable
- The relay or contactor on the soft-charge bypass relay is damaged
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa GA500 AC Drive code Uv1 mean?
The DC bus voltage dropped below the detection level, causing the drive to shut down the equipment.
Is Yaskawa GA500 AC Drive code Uv1 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa GA500 AC Drive code Uv1?
GA500 Installation & Primary Operation (TOEPC7106170Y), page 140.
How do I fix Yaskawa GA500 AC Drive code Uv1?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.