Yaskawa V1000 VFD
Yaskawa V1000 VFD code oL3: oL3 Overtorque Detection 1
The drive stopped the motor because the output current exceeded the programmed torque limit for too long.
- Code
- oL3
- Name
- oL3 Overtorque Detection 1
- Controller
- Yaskawa V1000 VFD
- Type
- General fault
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Overtorque Detection 1: The current has exceeded the value set for torque detection (L6-02) for longer than the allowable time (L6-03).
From the manufacturer's manual.
In plain words
The drive noticed the motor was pushing harder than the limit you set, for longer than allowed, so it flagged it. This is often a sign that something on the machine side is binding, jammed, or overloaded.
What usually sets it off
- Parameter settings L6-02 and L6-03 not appropriate for the load
- Fault on the machine side such as the machine being locked up or jammed
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Yaskawa V1000 VFD is commonly fitted on booths from Garmat USA and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa V1000 VFD code oL3 mean?
The drive stopped the motor because the output current exceeded the programmed torque limit for too long.
Is Yaskawa V1000 VFD code oL3 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa V1000 VFD code oL3?
The manufacturer's manual.
How do I fix Yaskawa V1000 VFD code oL3?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.