Yaskawa V1000 VFD
Yaskawa V1000 VFD code oH1: oH1 Overheat 1 (Heatsink Overheat)
The drive shut down because its heatsink temperature severely exceeded the maximum safe operating limit.
- Code
- oH1
- Name
- oH1 Overheat 1 (Heatsink Overheat)
- Controller
- Yaskawa V1000 VFD
- Type
- Over temperature
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Overheat 1 (Heatsink Overheat): The temperature of the heatsink has exceeded 10 degrees C plus the default value of L8-02.
From the manufacturer's manual.
In plain words
This is the higher-level heatsink overheat trip. Look for a hot room, blocked airflow, or a failing cooling fan.
What usually sets it off
- Surrounding temperature too high
- Poor air circulation inside the enclosure
- Load too heavy
- Carrier frequency set too high
- Internal cooling fan worn out or malfunctioning
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Yaskawa V1000 VFD is commonly fitted on booths from Garmat USA and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa V1000 VFD code oH1 mean?
The drive shut down because its heatsink temperature severely exceeded the maximum safe operating limit.
Is Yaskawa V1000 VFD code oH1 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa V1000 VFD code oH1?
The manufacturer's manual.
How do I fix Yaskawa V1000 VFD code oH1?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.