Yaskawa V1000 VFD
Yaskawa V1000 VFD code Uv1: Uv1 DC Bus Undervoltage
The drive stopped operating because its internal DC bus voltage fell below the minimum required level.
- Code
- Uv1
- Name
- Uv1 DC Bus Undervoltage
- Controller
- Yaskawa V1000 VFD
- Type
- Low voltage
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
DC Bus Undervoltage: While the drive was in operation the voltage in the DC bus fell below the undervoltage detection level (L2-05). For 200 V class approximately 190 V (160 V for single phase drives); for 400 V class approximately 380 V (350 V when E1-01 is less than 400).
From the manufacturer's manual.
In plain words
This usually points to a problem with the incoming power supply, such as a lost phase, a loose power terminal, low line voltage, or a brief power interruption.
What usually sets it off
- Input power phase loss
- Loose drive input power terminal
- Incoming supply voltage too low or out of range
- Power was interrupted
- Worn internal capacitors
- Undersized supply transformer causing voltage sag at startup
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Yaskawa V1000 VFD is commonly fitted on booths from Garmat USA and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa V1000 VFD code Uv1 mean?
The drive stopped operating because its internal DC bus voltage fell below the minimum required level.
Is Yaskawa V1000 VFD code Uv1 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa V1000 VFD code Uv1?
The manufacturer's manual.
How do I fix Yaskawa V1000 VFD code Uv1?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.