Yaskawa V1000 VFD code oL1: oL1 Motor Overload
The drive stopped the motor because the internal electrothermal sensor tripped the overload protection.
- Code
- oL1
- Name
- oL1 Motor Overload
- Controller
- Yaskawa V1000 VFD
- Type
- Motor overload
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Motor Overload: The electrothermal sensor tripped overload protection.
From the manufacturer's manual.
In plain words
The drive calculates how hot the motor is getting from how much current it draws over time, and it decided the motor was overworked. This protects the motor from burning up. It often means the motor is genuinely overloaded, running too slow for too long, or the motor rating was entered wrong.
What usually sets it off
- Load too heavy or too long at low speed
- Wrong motor rated current set in E2-01
- Motor base frequency set too low in E1-06
- Voltage too high for the V/f pattern
- Multiple motors running from one drive
- Input phase loss causing output current fluctuation
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Yaskawa V1000 VFD is commonly fitted on booths from Garmat USA and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa V1000 VFD code oL1 mean?
The drive stopped the motor because the internal electrothermal sensor tripped the overload protection.
Is Yaskawa V1000 VFD code oL1 dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa V1000 VFD code oL1?
The manufacturer's manual.
How do I fix Yaskawa V1000 VFD code oL1?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.