Yaskawa V1000 VFD
Yaskawa V1000 VFD code oC: oC Overcurrent
The drive stopped the motor because its sensors detected an output current exceeding the maximum limit.
- Code
- oC
- Name
- oC Overcurrent
- Controller
- Yaskawa V1000 VFD
- Type
- Overcurrent
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Overcurrent: Drive sensors have detected an output current greater than the specified overcurrent level.
From the manufacturer's manual.
In plain words
It usually means the load on the motor spiked, the motor tried to start against something jammed, or there is a short or ground problem in the motor or its wiring.
What usually sets it off
- Damaged motor or motor insulation
- Shorted or grounded motor cable
- Load is too heavy or changes suddenly
- Acceleration or deceleration time set too short
- Drive is undersized for the motor
- Output contactor opened or closed while the drive was running
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Yaskawa V1000 VFD is commonly fitted on booths from Garmat USA and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa V1000 VFD code oC mean?
The drive stopped the motor because its sensors detected an output current exceeding the maximum limit.
Is Yaskawa V1000 VFD code oC dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa V1000 VFD code oC?
The manufacturer's manual.
How do I fix Yaskawa V1000 VFD code oC?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.