Yaskawa V1000 VFD
Yaskawa V1000 VFD code oH: oH Heatsink Overheat
The drive stopped because its internal heatsink temperature exceeded the maximum programmed limit.
- Code
- oH
- Name
- oH Heatsink Overheat
- Controller
- Yaskawa V1000 VFD
- Type
- Over temperature
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Heatsink Overheat: The temperature of the heatsink exceeded the value set to L8-02. The default value for L8-02 is determined by drive capacity (o2-04).
From the manufacturer's manual.
In plain words
The metal heatsink that keeps the drive cool got too hot. This is commonly caused by a hot room, blocked airflow around the drive, or a cooling fan that has stopped or worn out.
What usually sets it off
- Surrounding temperature too high
- Poor air circulation inside the enclosure
- Load too heavy
- Carrier frequency set too high
- Internal cooling fan stopped or failed
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Yaskawa V1000 VFD is commonly fitted on booths from Garmat USA and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa V1000 VFD code oH mean?
The drive stopped because its internal heatsink temperature exceeded the maximum programmed limit.
Is Yaskawa V1000 VFD code oH dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa V1000 VFD code oH?
The manufacturer's manual.
How do I fix Yaskawa V1000 VFD code oH?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.