Yaskawa V1000 VFD
Yaskawa V1000 VFD code oV: oV Overvoltage
The drive stopped because its internal DC bus voltage exceeded the maximum safe detection level.
- Code
- oV
- Name
- oV Overvoltage
- Controller
- Yaskawa V1000 VFD
- Type
- High voltage
- What it does
- Fault: the equipment trips and stops
- Risk
- YELLOW Booth plays by its own rules
- Reset
- Needs a manual reset
- Source
- The manufacturer's manual
Updated July 22, 2026
How to fix it
Subscribers get:
- What to do next, in plain words
- The step by step check for this problem, one check at a time
- Booking a live video call with Ben, a master booth technician ($250/hr, paid per call)
What the manual says
Overvoltage: Voltage in the DC bus has exceeded the overvoltage detection level. For 200 V class approximately 410 V; for 400 V class approximately 820 V (740 V when E1-01 is less than 400).
From the manufacturer's manual.
In plain words
The internal DC voltage inside the drive climbed too high and it tripped to protect itself. This most often happens when the motor is slowing down or stopping and the spinning load feeds energy back into the drive faster than it can handle.
What usually sets it off
- Deceleration time too short so regenerated energy flows back into the drive
- Braking load too high with no braking resistor
- Incoming supply voltage too high
- Fast acceleration causing the motor to overshoot
- Ground fault in the output overcharging the DC bus
- Damaged or miswired braking transistor
Which of these it is on your booth, and what to do about it, is the step by step check in WERCS Diagnose.
Where you find this controller
On paint and spray booths, the Yaskawa V1000 VFD is commonly fitted on booths from Garmat USA and Accudraft Paint Booths. The same code means the same thing on any of them.
When to call a technician
A working electrician or maintenance tech can usually run this down, but a booth ties its fans, burner and safeties together in ways general equipment does not. If the code comes back after one careful pass, or the booth will not hold pressure or temperature afterward, call a booth technician. WERCS answers 24/7 at (877) 489-3727, and repairs every major booth brand.
Questions about this code
What does Yaskawa V1000 VFD code oV mean?
The drive stopped because its internal DC bus voltage exceeded the maximum safe detection level.
Is Yaskawa V1000 VFD code oV dangerous?
It is graded yellow: not hard, but a booth does it differently than the gear most techs know, so follow the checks in order.
Which manual documents Yaskawa V1000 VFD code oV?
The manufacturer's manual.
How do I fix Yaskawa V1000 VFD code oV?
The manual's fix and the step by step check for this code are in WERCS Diagnose, plans from $49 a month. For help right now, WERCS answers 24/7 at (877) 489-3727.